residual current circuit breaker ID Fi - 2 poles - 125 A - 30mA - class AC
This Acti9 RCCB-ID product is a residual current circuit breaker (RCCB).
- Range : Acti9
- Product name : Acti9 RCCB-ID
- Product or component type : Residual current circuit breaker (RCCB)
- Device short name : RCCB-ID
- Poles description : 2P
- Neutral position : Left
- [In] rated current : 125 A
- Network type : AC
- Earth-leakage sensitivity : 30 mA
- Earth-leakage protection time delay : Instantaneous
- Earth-leakage protection class : Type AC
- Rated breaking and making capacity : Im = 1250 A 230 V conforming to IEC 61008
- Rated conditional short-circuit current : Inc 10 kA 125 A
- Device location in system : Outgoer
- Network frequency : 50/60 Hz
- [Ue] rated operational voltage : 230 V AC 50 Hz conforming to IEC 61008
- Residual current tripping technology : Electromechanical
- [Ui] rated insulation voltage : 440 V AC 50 Hz conforming to IEC 61008-1
- [Uimp] rated impulse withstand voltage : 4 kV conforming to IEC 61008-1
- Control type : Toggle
- Mounting mode : Fixed
- Mounting support : 35 mm symmetrical DIN rail
- Connection pitch : 18 mm between phases
- 9 mm pitches : 4
- Height : 86 mm
- Width : 36 mm
- Depth : 76 mm
- Product weight : 230 g
- Colour : Grey
- Mechanical durability : 5000 cycles
- Electrical durability : 2000 cycles
- Provision for padlocking : Padlockable
- Connections - terminals : Tunnel type terminals2 cable(s) 1.5…16 mm² flexible Tunnel type terminals2 cable(s) 1.5…16 mm² rigid Tunnel type terminals1 cable(s) 1.5…50 mm² rigid Tunnel type terminals1 cable(s) 1.5…35 mm² flexible Tunnel type terminals1 cable(s) 1.5…35 mm² flexible with ferrule Tunnel type terminals2 cable(s) 1.5…16 mm² flexible with ferrule
- Wire stripping length : 11 mm
- Tightening torque : 3 N.m
Range | Acti9 |
Product name | Acti9 RCCB-ID |
Product or component type | Residual current circuit breaker (RCCB) |
Device short name | RCCB-ID |
Poles description | 2P |
Neutral position | Left |
[In] rated current | 125 A |
Network type | AC |
Earth-leakage sensitivity | 30 mA |
Earth-leakage protection time delay | Instantaneous |
Earth-leakage protection class | Type AC |
Rated breaking and making capacity | Im = 1250 A 230 V conforming to IEC 61008 |
Rated conditional short-circuit current | Inc 10 kA 125 A |
Device location in system | Outgoer |
Network frequency | 50/60 Hz |
[Ue] rated operational voltage | 230 V AC 50 Hz conforming to IEC 61008 |
Residual current tripping technology | Electromechanical |
[Ui] rated insulation voltage | 440 V AC 50 Hz conforming to IEC 61008-1 |
[Uimp] rated impulse withstand voltage | 4 kV conforming to IEC 61008-1 |
Control type | Toggle |
Mounting mode | Fixed |
Mounting support | 35 mm symmetrical DIN rail |
Connection pitch | 18 mm between phases |
9 mm pitches | 4 |
Height | 86 mm |
Width | 36 mm |
Depth | 76 mm |
Product weight | 230 g |
Colour | Grey |
Mechanical durability | 5000 cycles |
Electrical durability | 2000 cycles |
Provision for padlocking | Padlockable |
Connections - terminals | Tunnel type terminals2 cable(s) 1.5…16 mm² flexible Tunnel type terminals2 cable(s) 1.5…16 mm² rigid Tunnel type terminals1 cable(s) 1.5…50 mm² rigid Tunnel type terminals1 cable(s) 1.5…35 mm² flexible Tunnel type terminals1 cable(s) 1.5…35 mm² flexible with ferrule Tunnel type terminals2 cable(s) 1.5…16 mm² flexible with ferrule |
Wire stripping length | 11 mm |
Tightening torque | 3 N.m |